Discuss your challenges with our solutions experts

For details on how your data is used and stored, see our Privacy Notice.
Editorial

California's power market balancing act

Why the state won’t let go of nine gas plants set to retire this year

10 minute read

The California State Water Resources Control Board is set to meet on September 1, where they will vote on the extension of once-through-cooling (OTC) compliance deadlines for nine OTC gas plants set to retire at the end of this year – effectively delaying their retirement. The vote represents another rendition of the balancing act California is performing when it comes to achieving its renewable portfolio standards and climate goals while also maintaining grid reliability.

With well-cited concerns by entities including the California Energy Commission, California Public Utilities Commission, and CAISO, along with recent evidence showing the sensitivity of California’s supply stack, the board is expected to approve the extension for over 3.6 GW of thermal capacity in Los Angeles County.

So, what is the challenge at the heart of this balancing act and how does extending these units aide that effort?

The problem

In an analysis of California’s electric supply as well as statewide and local area grid reliability, the Statewide Advisory Committee on Cooling Water Intake Structures (SACCWIS) stated: “starting in the summer of 2021, additional power is likely needed for peak usage on hot days through 2023.” The committee, which advises the State Water Board on OTC policy, cited four major contributing factors driving this concern:

Shifts in peak demand to later in the day and later in the year when solar and wind resources are not as reliably available to meet peak demand; changes in the method for calculating the qualifying capacity of wind and solar resources resulting in lower qualifying capacity for these resources than previously determined; a significant increase in projected reliance on imported electricity over historical levels; and earlier-than-expected closures of some non-OTC power generating facilities

California Water Boards

Figure 1 below shows the recent evolution of CAISO’s net load curve during the high demand period of Q3 when we tend to see the yearly peak. The reduction in net load across the middle of the day has delayed peak gas demand to later in the evening and represents the high penetration of solar assets across hours 7:00-17:00 where there has been over a 20% decrease in net load from 2016. Another contributing factor to the downside that cannot be ignored is the decrease to demand this year from the coronavirus pandemic, which peaked at over 7% average hourly demand destruction in April and has generally been in the 1-2% range since June so far.

Figure 1: Average hourly net load (load net wind and solar) curves for Q3 by year (*2020 data through 08/02/2020). Source: CAISO

The growth of utility scale and the behind-the-meter solar generation caused much of the net load decrease, but with over 6.5 GW of renewable capacity coming online since the end of 2016, these resources have made only a minor dent in serving load at the most critical hours. Figure 2 below shows that from 2016, there has been only a 5% increase in average load hours 17:00-22:00 served by renewables compared to a 12% increase in average load served by renewables across all on peak hours, and a 26.6% increase in renewable capacity. This shows the diminishing returns of renewable capacity additions in terms of serving load at the evening peak demand hours.

Figure 2: Cumulative renewable capacity additions in CAISO by year and average percent of evening load served by renewables (*2020 capacity additions through May and average percent of load served through 08/02/2020). Source: EIA and CAISO

The second factor noted by the SACCWIS stated concerns over reliance on imported power greater than historical levels. This past summer has been a stark reminder that CAISO cannot rely on significant levels of imports to meet evening demand. Across the evening peak hours of 17:00-22:00, we have seen record low imports this summer which have averaged 6.5 GW for June and July compared to the 8.1 GW average from 2016-2019. Much of this has been driven by record low imports from the Balancing Authorities (BAs) in the southwest and even prolonged periods of exports when prices at Mead and Palo Verde (two major southwestern pricing hubs) trade at a premium to SP. Since July 1, 2020, imports during hours 17:00-22:00 from the southwest have averaged 920 MW compared to 2,450 MW and 2,480 MW across the same clip from 2019 and 2018 respectively. As other BAs across the west begin to accelerate their resource transitions away from coal and navigate reliability challenges, California is no longer able to rely on historic levels of import power when it is needed most.

The third factor refers specifically to renewable resources serving peak demand later in the year, when less favorable meteorological conditions call for reducing the dependability of wind and solar assets to a lower percentage of their nameplate capacities. For solar assets, this is intuitively driven by shorter days and fewer hours of sunlight. For wind assets, capacity factors decrease across the late summer months when temperatures are at their highest. For these reasons, the electric load carrying capability (ELCC) for solar generation is reduced from a high of 39% in July to 21% in August and 15% in September. Comparably, wind ELCCs are reduced to 21% in August and 15% in September from 23% in July. These lower ELCCs can be a problem for CAISO when demand is commonly at it’s highest and hydro resources in the state are past their peak reservoir levels - putting the onus on the retiring fleet of gas resources.

Finally, the advising committee cited the retirement of non-OTC gas plants as the fourth contributing factor. Just in the LA Basin, we’ve seen a few large non-OTC gas plants retire in the past two years – with around 1.7 GW of capacity lost from the Encina and Etiwanda generating stations coming offline due to economic reasons. However, this isn’t just a local grid reliability issue, as other units form around the state – including Inland Empire and Moss Landing representing around 2.2 GW of capacity lost – have come offline in recent years and present challenges related to statewide reliability. Additionally, with CAISO exposed to changing fleets in bilateral western markets, gas and coal retirements in neighboring states are a concern for reliability across the west.

The committee’s recommendation

The committee’s preferred recommendation calls for the extension of the remaining nine legacy AES corporation gas plants along the Los Angeles coast – representing over 3.6 GW of capacity.

Generator Name

Unit(s)

Approx. Capacity (MW)

Cur. Retirement Data

New Retirement Date

Alamitos

3, 4, 5

1, 160

12/31/2020

12/31/2023

Ormond Beach

1 & 2

1,490

12/31/2020

12/31/2023

Huntington Beach

2

225

12/31/2020

12/31/2023

Redondo

5, 6, 8

750

12/31/2020

12/31/2021

Figure 3: Alamitos, Ormond Beach, Huntington Beach, and Redondo all monitored facilities in our PowerRT product via EMF sensor or IR camera. Source: Genscape, a Wood Mackenzie business

Recent evidence

In approving the recommendation, the state would be ensuring these units be available if needed to serve load at times of peak demand. These scenarios arise when there is a high degree of coincident heat across the west and particularly when Southern California and the southwest see above normal temperatures at the same time. It can be common for Southern California and the southwest to see similar high temperatures, but what puts the California supply stack in a tight spot is when there are any unforeseen outages or constraints, which limit generation or transmission. That was the case July 30-31, when above normal temperatures across Southern California and the southwest timed up with Diablo Canyon Unit 2 (1,200 MW and 50% of the state’s nuclear capacity) still on a forced outage due to a trip less than two weeks prior. After being alerted of the trip in real time from PowerRT, it was noticeable that some of the OTC units were subsequently called online to help supplant the loss in base load generation.

The high load levels in Southern California and the southwest observed on these days led to real time energy prices spiking to $1,000 on July 30 and $690 on July 31. This sort of coincident demand has become a major risk to reliability in CAISO, as there has been a growing pull-back in imports when there are extreme load levels outside of California. Over the last two days of July, this was the case in the southwest which saw temperatures in the 110-degree range and as a result we saw real time exports near their maximum available transmission capacity on major southwest interties.

This level of coincident demand, and the ensuing pullback in imports, has another effect other than just higher energy prices across the system; it puts pressure on California’s Path 26, the major transmission backbone connecting Northern California to Southern California. Over the last two days of July, with mild load in the north and near record heat in the south, Path 26 was constrained and as a result congestion costs drove SP prices over $1,200 both days while NP peaked at $514 and $32 on July 30 and 31 respectively.

In figure 4 below, the estimated amount of generation from those OTC units under consideration has been backed out of the total thermal generation in California for July 30 and is shown in gold. This was calculated by calibrating which units were online based on real time monitors in PowerRT and how those units were dispatched in our SCED model. With very similar supply, imports, and demand for July 30 and 31, this figure shows the OTC units were critical to serving load and still could not prevent prices from spiking on both days.

Figure 4: Supply Stack on July 30, 2020 with NP and SP real time Locational Marginal Prices. Source: CAISO and Genscape, a Wood Mackenzie business

Future impacts

With storage set to flood the market, and particularly storage paired with solar, the percentage of peak load served by renewables will increase as more projects come online. Lately, news of Southern California Edison’s (SCE) new 770 MW storage procurement is reason to expect significant changes in the coming years. However, as it currently stands the largest project in the country recently came online in Southern California this past June, totaling 62.5 MW of capacity and only serving a negligible portion of peak demand.

As more storage capacity comes online over the next couple of years, it is likely that these OTC units will be dispatched less often. However, as California navigates the current liminal period of retiring gas and adding storage, this recommendation errs on the side of caution given potential delays in storage or complications in upstream markets. As California strives to meet the goals outlined in its integrated resource plan while also maintaining reliability, it exposes itself to times of high volatility in the wholesale market.

The extension of these units should help address the concerns around peak demand, providing reliable capacity and putting a downward pressure on wholesale prices. We’re following these changing circumstances to help market participants make more informed decisions. To learn more about our offerings or speak to an expert, fill out the form at the top of the page.

Addendum

Added August 15, 2020

The sensitivity of California’s supply stack, and how it relates to the reliability concerns outlined in the editorial, was on full display Friday, August 14 – with CAISO declaring its first stage 3 emergency since the California power crisis of 2001. Without any major unforeseen transmission or generation outages, the current heatwave across the west is testing California’s reliability at this crucial juncture of adding renewables and retiring thermal generation.

As shown in the figure below, the OTC units were yet again a critical portion of the gas fleet in the state, and our estimates accounted for around 8.5% of total natural gas supply across the evening demand hours of 17:00-22:00. Even with Friday’s day-ahead market clearing at the greatest SP heat rate ever of 48.00 for the on-peak period, the available supply in California could not prevent the ISO from dipping into its operating reserves and initiating rotating power outages.

With the State Water Board set to consider the reliability concerns outlined by SACCWIS in just over two weeks, this distressing event serves as more recent evidence as to why the board is expected to approve the recommendation.

Figure 5: Supply Stack on August 14, 2020 with NP and SP real time Locational Marginal Prices. Source: CAISO and Genscape, a Wood Mackenzie business